Know-howmakes the difference
19
An
Company
B-1210-UK-02-2014-REV.B
Size øA B C D D1 D2 øI øJ
L
N *N øp Q øR øT W W1 øU øV
Weight
(kg)
ISO
5211
DN15 15 9 139 49
7.0
85 36 42 41 4
4 65 M12 45
82.0 16 2
6.0
6
1.3
F03 / F04
DN20 20 9 139 54
8.0
90 36 42 44 4
4 75 M12 58
98.6 18 2
6.0
6
2.0
F03 / F04
DN25 25 11 165 65 12.0 104 40 50 50 4
4 85 M12 68 115.0 18 2
6.0
7
2.8
F04 / F05
DN32 32 11 165 77 11.3 116 40 50 60 4
4 100 M16 78 140.0 18 2
6.0
7
4.2
F04 / F05
DN40 38 14 215 86 15.5 135 50 70 65 4
4 110 M16 88 150.0 18 3
7.5
9
5.3
F05 / F07
DN50 50 14 215 93 16.0 142 50 70 80 4
4 125 M16 102 165.0 18 3
7.5
9
6.7
F05 / F07
DN65 65 17 263 110 15.8 168 70 102 110 4
8 145 M16 122 185.0 22 3 10.0 12
11.9
F07 / F10
DN80 80 17 313 120 16.0 178 70 102 120 8
8 160 M16 138 200.0 24 3 10.0 12
14.9
F07 / F10
Size
øA
B
C
D
*D
D1
D2
*D2
ø I
ø J
L
N
øP
DN100
100
17
344
131.7
132.7
17.8
190
191
70
102
150
8
180
*øP
øQ *øQ øR
*øR
ø T
*ø T
W *W W1
øU
øV
Weight
(kg)
ISO
5211
190
M16
M20
158
162
220
235
20
24
3
10
12
20.38
F07/F10
Dimensions type1500 stainless steel and1501 steel
Dim.
* Torque [Nm]
Kv-value [m³/h at 1bar] Weightwithhandle
[MM]
Break away torque
90° fully open
[kg]
15
9.6
24
1.30
20
12.0
43
1.96
25
20.4
81
2.80
32
31.2
112
4.15
40
40.8
221
5.25
50
51.6
412
6.66
65
81.6
680
11.88
80
93.6
1063
14.90
100
112.8
1913
20.38
*) Torque figures included 30% safety factor. (TEST: 0bar diff. pressure, ambient temperature, Non-lubricating)
When dimensioning the actuator followingmust be added: - 15% if lubricatingmedias.
MEDIA FACTOR
MULTIPLIER
Clean, particle free, non-lubricating (water, alcohol, etc)
1.00
Clean, particle free, lubricating (oils, hydraulic fluid, etc)
0.80
Slurries or heavily corroded, solvents and contaminated systems
2.00#
Gas or saturated steam, clean andwet
1.00
Gas or superheated steam, clean and dry
1.30
Gas, dirty unfiltered e.g. natural gas, Chlorine
1.50
SERVICE FACTOR
MULTIPLIER
Simple On andOff Operations
1.00
Throttling
1.20
Positioner Control
1.50
Once per day Operations
1.20
Once every two days or a “Plant Critical” Operation
1.50
Max differential pressure
(DN15-32 PN40) 1.50
(DN40-50 PN40) 2.00
(DN65-100 PN16) 2.80