16
Know-howmakes the difference
B-1210-UK-02-2014-REV.B
An
Company
Dimensions type1212 steel
F - Full bore
Dim.
Valvewithhandle
Weld ends
DN Aweld B
C
E
F
J
K ISO 5211 G øGx4 ISO 5211 H øHx4 I
D
10 225 11.6 35.1 72.0 114 10 18
F03
36
5.5
-
-
-
9
6.7
15 225 12.7 35.1 72.0 114 15 21.8 F03
36
5.5
-
-
-
9
6.7
20 225 15.0 40.5 77.0 114 20 28
F03
36
5.5
F04
42 5.5
9
8.0
25 245 20.0 50.5 87.0 114 25 34
F03
36
5.5
F04
42 5.5
9
9.6
32 255 25.4 50.5 91.0 133 32 43
F04
42
5.5
F05
50 6.5 11 12.5
40 260 31.8 60.0 99.0 187 40 49
F04
42
5.5
F05
50 6.5 11 12.6
50 275 38.1 77.0 116.0 187 50 61
F05
50
6.5
F07
70 8.5 14 16.1
65 F 334 65.0 93.0 147.0 315 70 8.5
F07
70
8.5
-
-
-
17 28.5
80 354 76.0 113.0 167.0 315 82 88.9 F07
70
8.5
-
-
-
17 30.0
100 365 100.0 137.0 187.0 315 105 114.3 F07
70
8.5
F10 102 10.5 19 31.5
Dimension *) Torque
Weight
Kv-value
[mm]
[inch]
FB
[Nm]
FB [kg]
90°m³/t
FB
DN08
1/4”
11
0.63
6.8
DN10
3/8”
11
0.63
6.8
DN15
1/2”
11
0.66
12.8
DN20
3/4”
14
0.82
29.1
DN25
1”
20
1.25
47.8
DN32
1 1/4”
31
1.94
72.6
DN40
1 1/2”
42
3.15
106.8
DN50
2”
59
4.56
213.7
DN65
2 1/2”
82
9.01
273.3
DN80
3”
121
12.30
495.3
DN100
4”
149
21.54
871.1
*) Torque figures included 30% safety factor. (TEST: 0bar diff. pressure, ambient temperature, Non-lubricating)
When dimensioning the actuator followingmust be added: - 15% if lubricatingmedias.
MEDIA FACTOR
MULTIPLIER
Clean, particle free, non-lubricating (water, alcohol, etc)
1.00
Clean, particle free, lubricating (oils, hydraulic fluid, etc)
0.80
Slurries or heavily corroded, solvents and contaminated systems
2.00#
Gas or saturated steam, clean andwet
1.00
Gas or superheated steam, clean and dry
1.30
Gas, dirty unfiltered e.g. natural gas, Chlorine
1.50
SERVICE FACTOR
MULTIPLIER
Simple On andOff Operations
1.00
Throttling
1.20
Positioner Control
1.50
Once per day Operations
1.20
Once every two days or a “Plant Critical” Operation
1.50
Max differential pressure
(DN08-32 PN64) 1.50
(DN40-50 PN64) 2.00
(DN65-100 PN50) 2.80
Basic Torque*Media Factor *Service Factor = Sizing Torque
#Usingball valves in contaminated systemswill reduce life time